Item6Appendix1Plans20220172DETSkiTowCompress
CAIRNGORMS NATIONAL PARK AUTHORITY Planning Committee Agenda Item 6 Appendix | 23/09/2022
AGENDA ITEM 6
APPENDIX I
2022/0172/DET
PLANS
Cas Tow Shieling Building Piste Machine Garage Anchor block permanent Fixed position Scottish Ski Club Mid Station Funiculat Railway 0 m 10 m 20 m 30 m 40 m 50 m M1 Poma Location Plan Scottish Ski Club rope tow — movable. Contours shown at 1 metre intervals.
-01 1103 111 00 Smoothing ground works to reduce old white lady tow track cutting improving landscape appearance. Site Boundary extents Notes For ground profiles refer to detailed drawings. There is no ground manipulation along the length of the rope. The correct profile will be achieved with snow grooming, this replaces the need for fill material. The rope tow is designed to be movable with the anchor blocks remaining in a permanent fixed position. Direction of rope tow is anti clockwise. PDF to scale when viewed at 100% Scale 1 to 500. or printed at A1. Grid References Lower anchor block — NH99636 05363. Upper anchor block — NH99816 05248. Rope tow Drive unit movable + + 0 m 10 m 20 m 30 m 40 m 50 m NORTH Drawn by JC. March 22. White Lady Piste Dissused White Lady Track cutting SSC Rope Tow Rope tow return unit movable Anchor block permanent Fixed position White Lady Piste
758 FENCE (by customer) At least 1m above snow-level ~6m Oft 50ft DRAWING OF TERRAIN: SUNKID COMFORT STAR: 2M-T‑A DISTANCE WHEEL-WHEEL: LENGTH (ENTRANCE-EXIT): DETAIL TRACE (M 1⁄75) DRIVEWAY SIDE LEFT LIFT MIDDLE WHEELØ 1,5m شه 702 ft (214 m) 665 ft (202,7 m) DETAIL TRACE (M 1⁄75) DRIVEWAY SIDE LEFT LIFT MIDDLE WHEELØ 1,5m 758 FENCE (by customer) At least 1m above snow-level FENCE (by customer) At least 1m above snow-level
~6m Oft 50ft DRAWING OF TERRAIN: SUNKID COMFORT STAR: 2M-T‑A DISTANCE WHEEL-WHEEL: DETAIL TRACE (M 1⁄75) DRIVEWAY SIDE LEFT LIFT MIDDLE WHEELØ 1,5m شه 702 ft (214 m) LENGTH (ENTRANCE-EXIT):
Piste Machine Garage Power supply from existing hut 750 m Cas Tow 152 m 753 m Shieling Building 753 m 755 756m 780 Anchor block permanent Fixed position Scottish Ski Club Mid Station Funicular Railway 0 m 10 m 20 m 30 m 40 m 50 m M1 Poma 775 Rope tow Drive unit movable 773m White Lady Piste 787m 800m 794 m Cable route and access Plan Scottish Ski Club rope tow — movable. Contours shown at 1 metre intervals. Smoothing ground works to reduce old white lady tow track cutting improving landscape appearance. CAIRNGORM MOUNTAIN SCOTLAND Lower site extents Upper site extents — minimised to accomodate anchor block. Power cable route from hut to base of lift Safety cable route from drive unit to return unit Access route on existing track for plant and materials to site corridor Scale 1 to 500. PDF to scale when viewed at 100% or printed at A1. Notes For ground profiles refer to detailed drawings. There is no ground manipulation along the length of the rope. The correct profile will be achieved with snow grooming, this replaces the need for fill material. The rope tow is designed to be movable with the anchor blocks remaining in a permanent fixed position. Grid References Lower anchor block — NH99636 05363. Upper anchor block — NH99816 05248. + 0 m 10 m 20 m Track cutting 30 m 40 m 50 m NORTH Drawn by JC. June 22. Rope tow return unit movable Anchor block permanent Fixed position White Lady Piste
SHOWN: DRIVE UP SIDE — LEFT BOTTOM STATION SHOWN Gezeichnet: Auffahrtsseite — Links Talstation gezeichnet SAFETY GATE “5.12 — WINDOW” Überfahrsicherung “5.12 — Fenster” HANDLE GUIDANCE Bügelservice BARRIER Skianschlag HOIST + CHAIN HYDRAULIC PUMP lifting + lowering (depends on project) Hydraulikpumpe Greifzug + Kette (projektabhängig) anheben + absenken FORCE GAUGE Kraftmesser DEAD MAN ANCHORING (DIMENSIONS ACCORDING TO LOCAL RULINGS) Totmann — Abspannung (Abmessung laut örtl. Vorschriften) T/B DRIVING UNIT 3,0 – 11kW Antriebseinheit 3,0 – 11kW ENTRANCE Einstieg ~1.2m-~4’ AT LEAST 3m EVEN mind. 3m eben FENCE (by Customer) (at least 1m above snow) Einzäunung (kundenseitig) (mind. 1m über Schnee) ENTRANCE AREA >2m/7’ — EVEN Einstiegsbereich mind. 2m eben 4m/13’ + 2% of LIFT-LENGTH 4m + 2% der Liftlänge ROPE HEIGHT >0.95m/3’ Seilhöhe mind. 0.95m DETAIL HEIGHT-ADJUSTMENT Detail Höhenverstellung BASEFRAME: STEEL-HOT DIP GALVANIZED Grundgestell: Stahl-feuerverzinkt STEEL ROPE Ø9mm WITH “COMFORT” PLATTER HANGERS Stahlseil Ø9mm mit “COMFORT”-Tellerbügel OPTIONAL: ELECTRO-HYDRAULICAL HEIGHT-ADJUSTMENT Option: Elektrohydraulische Höhenverstellung HEIGHT ADJUSTMENT: Höhenverstellung: 0.95m‑2.8m / 3’-9’ OPTION SLED “GLACIER-STYLE” (according to allowed Terrain-Pressure) Option “Gletscherschlitten” (laut zulässigem Bodendruck) BARRIER Skianschlag HANDLE GUIDANCE Bügelservice DISTANCE: >2m/7’ Abstand mind. 2m >1.5m/5’ mind. 1.5m LIFT MIDDLE Lift Mitte SLED 3.9m/13’ Grundschlitten 3.9m SLED-GUIDANCE 6m Führungsschienen 6m Diese Unterlagen sind Elgentum der Firma Bruckschlög GesmbH, 4822 Bad Goisern und dürfen als Ganzes oder tellwelse weder vervielfältigt noch Drittpersonen zugänglich gemacht werden ohne die schriftliche Zustimmung der Elgentümer. Zuwiderhandlungen verpflichten zu Schadenersatz. / These documents remain the sole property of Bruckschlög GesmbH, 4822 Bad Golsern and must not be copled or reproduced In whole or in part or made avallable to third partles without written permission from the owners. Vlolation obligates compensation for damages. Projekt/project: DRIVE STATION TYPE “2” ENTRANCE + DEAD MAN ANCHOR Antriebstation Type “2” Einstieg + Totmann Abspannung erstellt durch: created by: EB Hersteller/Manufacturer: BRUCKSCHLÖGL GES.M.B.H MASCHINENBAU-FÖRDERTECHNIK-SEILBAHNTECHΝΙΚ A‑4822 Bad Goisern am Hallstättersee / Au 132 Sumkid Ansprechpartner: UB Representatives: erstellt mit AutoCAD LT 2014 Produkt/product: Baurelhe/Model range CS 26 SUNKID COMFORT STAR Datum/Date 04.02.2021 Maßstab/Scale Detalls/detalls: STAR LIFTS HYDRAULIC HEIGHT ADJUSTMENT 0,9 – 2,8m 1:50 (A3) EDV Nr.: m21-20 – 102_Type2M_TOTMANN Seiten/Pages 1⁄1